Jinlang Single-Phase Low-Voltage Energy Storage Inverter S6-EH1P (3–8)kW – L – PLD
Inquiry for a quote
Keywords:
Jinlang Technology
Detailed Introduction
Product Features
• UPS rating and off-grid switching
• Maximum charge and discharge current of 190 A
• 6-stage timed charge/discharge function
• 2× output for 10 seconds of off-grid load‑carrying capability
• Multiple methods for connecting to the generator, enabling automatic start-up and shutdown control.
• Supports single-phase or three-phase grid‑connected parallel operation, with a maximum system capacity of 48 kW.
• Offers an AC‑coupling solution, facilitating the retrofitting of grid‑connected power plants.
• Supports the “PeakShaving” function in both self-consumption and generator modes.
• Supports lithium-ion and lead-acid batteries, with integrated battery management and protection.
Product model
S6-EH1P3K-L-PLD / S6-EH1P3.6K-L-PLD S6-EH1P5K-L-PLD / S6-EH1P6K-L-PLD
S6-EH1P8K-L-PLD
| Technical Specification Sheet | S6-EH1P(3-8)K-L-PLD | |||||
| Product model | 3K | 3.6K | 5K | 6K | 8K | |
| DC Input (PV Side) | ||||||
| Maximum allowable input power | 4.8 kW | 5.76 kW | 8 kW | 9.6 kW | 12.8 kW | |
| Maximum input voltage | 500 V | |||||
| Rated input voltage | 330 V | |||||
| Starting voltage | 90 V | |||||
| MPPT voltage range | 90-435 V | |||||
| Maximum input current | 16 A / 16 A | 32A / 32 A | ||||
| Maximum input short-circuit current | 20 A / 20 A | 40 A / 40 A | ||||
| Number of MPPTs / Maximum Number of Input Strings | 2/2 | 2/4 | ||||
| Battery | ||||||
| Battery type | Lithium battery / Lead-acid battery | |||||
| Battery voltage range | 40-60 V | |||||
| Maximum charge/discharge power | 3 kW | 3.6 kW | 5 kW | 6 kW | 8 kW | |
| Maximum charge/discharge current | 70 A | 80 A | 112 A | 135 A | 190 A | |
| Communication method | CAN/RS485 | |||||
| AC Output (Grid Side) | ||||||
| Rated output power | 3 kW | 3.6 kW | 5 kW | 6 kW | 8 kW | |
| Maximum output apparent power | 3 kVA | 3.6 kVA | 5 kVA | 6 kVA | 8 kVA | |
| Rated grid voltage | 1/N/PE, 220 V / 230 V | |||||
| Rated grid frequency | 50 Hz / 60 Hz | |||||
| Rated grid output current | 13.7 A / 13.1 A | 16.4 A / 15.7 A | 22.8 A / 21.8 A | 27.3 A / 26.1 A | 36.4 A / 34.8 A | |
| Maximum output current | 13.7 A / 13.1 A | 16.4 A / 15.7 A | 22.8 A / 21.8 A | 27.3 A / 26.1 A | 36.4 A / 34.8 A | |
| Output power factor | >0.99 (0.8 leading ... 0.8 lagging) | |||||
| Total Current Harmonic Distortion Rate | <2% | |||||
| AC Input (Grid Side) | ||||||
| Input voltage range | 187-253 V | |||||
| Maximum input current | 21 A | 25 A | 32 A | 40 A | 50 A | |
| Frequency range | 45-55 Hz / 55-65 Hz | |||||
| AC Output (Off-Grid Side) | ||||||
Rated output power | 3 kW | 3.6 kW | 5 kW | 6 kW | 8 kW | |
| Maximum output apparent power | Supports 10 seconds of continuous output at twice the rated power. | |||||
| And grid‑off switching time | <4 ms | |||||
| Rated output voltage | 1/N/PE, 220 V / 230 V | |||||
| Rated frequency | 50 Hz / 60 Hz | |||||
| Rated output current | 13.7 A / 13.1 A | 16.4 A / 15.7A | 22.8 A / 21.8 A | 27.3 A / 26.1 A | 36.4 A /3 4.8 A | |
| Maximum output current | 35 A | 35 A | 40 A | 40 A | 50 A | |
| Maximum bypass current | 35 A | 35 A | 40 A | 40 A | 50 A | |
| Total Voltage Harmonic Distortion Rate | <2% | |||||
| Efficiency | ||||||
| Maximum efficiency | 97.5% | |||||
| European Efficiency | 96.5% | |||||
| Maximum charging efficiency of the PV system | 95.3% / 93.9% | |||||
| Maximum charge–discharge efficiency of the battery | 93.8% | |||||
| Protection | ||||||
| Ground Fault Detection | possessing | |||||
| DC Reverse Polarity Protection | possessing | |||||
| Integrated AFCI (Arc Fault Circuit Interrupter) | Optional | |||||
| Protection Level / Overvoltage Type | Level 1 / Level 2 (photovoltaic port and battery port), Level 3 (grid port, off-grid port, and generator port) | |||||
| Basic Parameters | ||||||
| Dimensions (Width × Height × Depth) | 335*560*227 mm | |||||
| Weight | 21.6kg | 22.2kg | ||||
| Topology | High-Frequency Isolation (Battery) | |||||
| Operating ambient temperature | -40 ~ +60° C | |||||
| Protection rating | IP66 | |||||
| Noise (typical) | <40dB(A) | <58dB(A) | ||||
| Cooling method | Natural cooling | Intelligent Redundant Air Cooling | ||||
| Maximum operating altitude | 4000 m | |||||
| Grid-connection standard | NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA | |||||
| Safety / EMC Standards | IEC/EN 62109-1/-2, EN 61000-6-2/-3 | |||||
| Characteristics | ||||||
| DC port | MC4 connector (PV port) / Terminal block (battery port) | |||||
| Communication port | Terminal block | |||||
| Display screen | LED + APP | |||||
| Communication method | RS485 / CAN / Wi‑Fi (optional) / GPRS (optional) / LAN (optional) | |||||
Packaging and shipping
Customer visit
Customer Feedback
Quotation Inquiry
Please fill in your Contact Us information and your requirements, and we will arrange for a specialist to get in touch with you!
Jinlang Single-Phase Low-Voltage Energy Storage Inverter S6-EH1P (3–8)kW – L – PLD
Inquiry for a quote
Keywords:
Jinlang Technology
Contact Us
Service Hotline (8:00–18:00): 400-682-5699
Phone: +86-15689558243
Corporate email: anyujt@163.com
Address: No. 3566, Chongde Avenue No. 1, Economic Development Zone, Dezhou City, Shandong Province