Jinlang Single-Phase High-Voltage Energy Storage Inverter S6-EH1P (3.8–11.4) kV-H-US
Inquiry for a quote
Keywords:
Jinlang Technology
Detailed Introduction
Product Features
• 4 MPPT channels, with a string current of 16 A, enabling greater flexibility in photovoltaic array design.
• Offers a choice of multi-brand optimizers and fast shutdown devices, supporting module-level monitoring.
• Supports external RSD and EPO switches, and features a mains bypass switch.
• Holds UL 9540 certification for batteries from multiple brands (e.g., LG, BYD, Pylontech)
• Connects to the mobile app via Bluetooth for more convenient debugging.
• UPS-grade and off‑grid switching, supporting a 1.7‑times (130 A) off‑grid load‑carrying capability for 150 ms.
• Offers an AC‑coupling solution, facilitating the retrofitting of grid‑connected power plants.
• When paired with the Solis Hub, it can integrate with generators to provide whole-house backup power and intelligent load management.
• Supports single-phase (split-phase) or three-phase grid‑connected parallel operation.
Product model
S6-EH1P3.8K-H-US
S6-EH1P5K-H-US
S6-EH1P7.6K-H-US S6-EH1P9.9K-H-US
S6-EH1P10K-H-US
S6-EH1P11.4K-H-US
| Technical Specifications Sheet | S6-EH1P(3.8-11.4)K-H-US | |||||
| Product model | 3.8K | 5K | 7.6K | 9.9K | 10K | 11.4K |
| DC Input (PV Side) | ||||||
| Maximum input voltage | 600V | |||||
| Rated input voltage | 380V | |||||
| Starting voltage | 80V | |||||
| MPPT voltage range | 80-520V | |||||
| Maximum input current | 16A | |||||
| Maximum input short-circuit current | 25.6A | |||||
| Number of MPPTs / Maximum Number of Input Strings | 2/1 | 3/1 | 4/1 | |||
| Battery | ||||||
| Battery type | High-voltage lithium battery | |||||
| Battery voltage range | 120-500V | |||||
| Maximum charge/discharge current | 25A | 50A | ||||
| Communication method | CAN/RS485 | |||||
| AC Output (Grid Side) | ||||||
| Rated output power | 3.8kW | 5kW | 7.6kW | 9.99kW | 10kW | 11.4kW |
| Maximum output apparent power | 3.8kVA | 5kVA | 7.6kVA | 9.99kVA | 10kVA | 11.4kVA |
| Rated output voltage | 220V/240V | |||||
| Rated frequency | 60Hz | |||||
| Rated output current | 17.3A/15.8A | 22.7A/20.8A | 34.5A/31.7A | 45.5A/41.7A | 45.5A/41.7A | 51.8A/47.5A |
| Maximum output current | 17.3A/15.8A | 22.7A/20.8A | 34.5A/31.7A | 45.5A/41.7A | 45.5A/41.7A | 51.8A/47.5A |
| Total Current Harmonic Distortion Rate | <3% | |||||
| AC Input (Grid Side) | ||||||
| Input voltage range | 193.6-242V/211-264V | |||||
| Maximum input current | 25.9A/23.8A | 34.1A/31.2A | 51.8A/47.6A | 68.2A/62.6A | 68.2A/62.6A | 77.7A/71.3A |
| Frequency range | 59.5-60.5Hz/58.8-61.2Hz | |||||
| AC Output (Off-Grid Side) | ||||||
| Rated output power | 3.8kW | 5kW | 7.6kW | 9.99kW | 10kW | 11.4kW |
| Maximum output apparent power | 6.1 kVA, 10 sec | 8 kVA, 10 sec | 12.2 kVA, 10 sec | 16 kVA, 10 sec | 16 kVA, 10 sec | 18.2 kVA, 10 sec |
| And grid‑off switching time | <10ms | |||||
| Phase power | 220V/240V Split-Phase | |||||
| Rated Output Voltage (L1-L2) | 220V/240V | |||||
| Output voltage range | 193.6-242V/211-264V | |||||
| Rated grid frequency | 60Hz | |||||
| Frequency range | 55-65Hz | |||||
| Rated output current | 17.3A/15.8A | 22.7A/20.8A | 34.5A/31.7A | 45.5A/41.7A | 45.5A/41.7A | 51.8A/47.5A |
| Maximum output overcurrent protection, 10 sec | 27.7A/25.4A | 36.4A/33.3A | 55.5A/50.7A | 72.7A/66.7A | 72.7A/66.7A | 82.7A/76A |
| Upper limit of phase imbalance | 100% | |||||
| The backup port can connect to load types. | Household Loads and Specialized Loads | |||||
| Output power factor | >0.99 (0.8 leading ... 0.8 lagging) | |||||
| Total Voltage Harmonic Distortion Rate | <3% | |||||
| Efficiency | ||||||
| Maximum efficiency | 97% | 97.6% | ||||
| CEC efficiency | 96.5% | 97% | ||||
| Maximum efficiency of PV charging the battery | 98.5% | |||||
| The maximum efficiency of charge and discharge at the interface | 97.0% | |||||
| Protection | ||||||
| Ground Fault Detection | possessing | |||||
| Residual Current Detection | possessing | |||||
| Integrated AFCI (Arc Fault Circuit Interrupter) | possessing | |||||
| DC reverse connection protection | possessing | |||||
| Manual Inverter Bypass Switch | possessing | |||||
| Quick Shutdown NEC 2017 | possessing | |||||
| Compatible with RSD receivers | possessing | |||||
| Protection Level / Overvoltage Type | Level 1 / Level 2 | |||||
| Basic Parameters | ||||||
| Dimensions (Width × Height × Depth) | 490*720*220 mm | 560*750*220 mm | ||||
| Weight | 23.8kg | 32.5kg | ||||
| Topology | Transformerless | |||||
| Nighttime self-consumption electricity | < 20 W | |||||
| Operating ambient temperature | -25 ~ +60℃ | |||||
| Protection rating | TYPE 4X | |||||
| Noise (typical) | <30dB(A) | |||||
| Cooling method | Natural cooling | |||||
| Installation Type | Wall-mounted | |||||
| Maximum operating altitude | 4000m | |||||
| Standard | UL1741SB, UL1741SA, IEEE1547-2018, UL1699B, UL1998, FCC Part 15 Class B, California Rule 21, NEC 690.12-2020, CAN/CSA C22.2107.1-1 | |||||
| Generator | Support | |||||
| Characteristics | ||||||
| DC port | Sides and bottom (2 × 25.4 mm holes); uses spring terminals | |||||
| Communication port | Sides and bottom (3 × 38.1 mm holes); uses spring terminals | |||||
| Display screen | LED + Bluetooth + App | |||||
| High-precision electricity meter | Optional (Integrated ANSI C12.20) | |||||
| Monitoring platform | Jinlang Cloud (supports shared Modbus and APIs) | |||||
| Communication method | RS485 / Cellular (optional) / Wi‑Fi (optional) / LAN (optional) | |||||
Packaging and shipping
Customer visit
Customer Feedback
Quotation Inquiry
Please fill in your Contact Us information and your requirements, and we will arrange for a specialist to get in touch with you!
Jinlang Single-Phase High-Voltage Energy Storage Inverter S6-EH1P (3.8–11.4) kV-H-US
Inquiry for a quote
Keywords:
Jinlang Technology
Contact Us
Service Hotline (8:00–18:00): 400-682-5699
Phone: +86-15689558243
Corporate email: anyujt@163.com
Address: No. 3566, Chongde Avenue No. 1, Economic Development Zone, Dezhou City, Shandong Province