6 Major Technical Solutions
1. AC/DC Separation Architecture Design
2. Easy-to-use, low-maintenance platform technology
3. All-in-one integrated design for power electronics
4. Triple Security Protection Technology
5. Open Software Compatibility Technology
6. Full-environment adaptation and thermal management optimization technologies
AC/DC Separation Architecture Design
AC–DC isolation, plug-and-play installation and deployment
![]() | ![]() | ![]() | ![]() |
| Structural separation | Safe separation | Thermal separation | Protective separation |
Technical Specification Sheet EverCore-(100-261)kWh-(50-125)kW-NV
Model number | 100kWh-50kW | 120kWh-60kW | 261kWh-125kW |
System | |||
Rated capacity | 100.48 kWh | 120.57 kWh | 261.24 kWh |
Maximum charge/discharge rate | 0.5 P | ||
Maximum cycle efficiency | 89% | ||
Depth of charge and discharge | 0~100% | ||
Dimensions (Width × Height × Depth) | 1250 × 2030 × 1540 mm | 1850 × 2230 × 1600 mm | |
Dimensions (without inverter) (Width × Height × Depth) | 950 × 2030 × 1540 mm | 1400 × 2230 × 1600 mm | |
Weight | 1490 kg (battery cabinet) + 73 kg (inverter) | 1630 kg (battery cabinet) + 73 kg (inverter) | 2000 kg (battery cabinet) + 170 kg (inverter) |
Operating temperature range | -25 ~ +55°C | ||
Storage temperature range | 0 ~ +49°C | ||
Operating humidity range | ≤ 95% (no condensation) | ||
Maximum operating altitude | 4000 m | ||
System temperature control method | Industrial-grade air conditioning (battery cabinets; air-cooled packages); intelligent air cooling (inverters) | ||
Fire suppression method | Standard configuration: aerosol fire suppression system, explosion-proof pressure relief valve, water-based fire suppression, and audible‑visual alarm; Optional accessories: combustible gas detector, smoke detection, and explosion-proof ventilation system. | ||
Protection rating | IP55 (battery cabinet) + IP66 (inverter) | ||
Corrosion Protection Grade (Battery Cabinet) | C4, C5 (optional) | ||
Corrosion Resistance Grade (Inverter) | C5 | ||
Noise (rated operating condition) | 70 dB(A) @ 1 m | 75 dB(A) @ 1 m | |
Lightning protection level | AC Secondary / DC Secondary (Photovoltaic & Battery) | ||
Protection method | Anti-islanding protection, residual current detection, insulation impedance monitoring, AC overcurrent protection, and protection against incorrect AC cable connections, among others. | ||
Certification Standards | IEC62619, IEC61000-6-2/4, IEC62040, IEC63056, IEC62477, UN38.3 | ||
Battery | |||
Cell type | LFP 3.2 V / 314 Ah | ||
Cell cycle life | 8000 | ||
System Battery Configuration | 1P105 | 1P125 | 1P265 |
Rated voltage | 320 V | 384 V | 832 V |
Operating voltage range | 290 ~ 360 V | 348 ~ 432 V | 754 ~ 936 V |
Rated current | 157 A | ||
Number of battery packs | 5 | 6 | 13 |
Battery pack capacity | 20.08 kWh | ||
Battery pack weight | 198 kg | ||
Inverter | |||
Product model | G6-EH3P50K04-NV-YD-H | G6-EH3P60K04-NV-YD-H | G6-EH3P125K10-NV-YD-H |
Rated output power | 50 kW | 60 kW | 125 kW |
Maximum output apparent power | 50 kVA | 60 kVA | 125 kVA |
Rated grid voltage | 3/N/PE, 220 V / 380 V | ||
Rated grid frequency | 50 Hz | ||
Communication frequency range | 45 - 55 Hz | ||
Rated output current | 76 A | 91.2 A | 189.9 A |
Maximum output apparent power | 1.5 times the rated overload, for 10 s; 1.6 times the rated overload, for 2 s | 1.2 times the rated overload, for 100 s; 1.4 times the rated overload, for 10 s; 1.6 times the rated overload, for 200 ms | |
And grid‑off switching time | ≤ 20 ms | ||
Power factor | > 0.99 (0.8 leading to 0.8 lagging) | ||
Total Current/Voltage Harmonic Distortion Rate | < 2% / < 3% | ||
Recommended Maximum PV Module Power | 100 kW | 250 kW | |
Maximum Available PV Input Power | 100 kW | 250 kW | |
Maximum input voltage | 1000 V | ||
Rated voltage | 600 V | ||
Starting voltage | 180 V | ||
MPPT voltage range | 150 - 850 V | 150 - 950 V | |
Maximum input current | 4 × 42 A | 10 × 42 A | |
Maximum short-circuit current | 4 × 60 A | 10 × 60 A | |
Number of MPPTs / Maximum number of input strings per phase | 4 / 8 | 10 / 20 | |
Communication | 4G (data acquisition), CAN-BMS × 2, CAN-Parallel × 2, RS485-Meter, RS485, DRM, DI × 3, DO × 3 | 4G (data acquisition), CAN-BMS × 2, CAN-Parallel × 2, RS485-Meter, RS485, DRM, DI × 5, DO × 4 | |
Maximum number of parallel units (in parallel/stand-alone mode) | 10 | ||
① Rated operating conditions: Test conditions based on an ambient temperature of 25±2°C, a charge–discharge rate of 0.5P, and an AC output voltage of 380 or 400 V.
② This data is provided by the cell manufacturer. It is based on test conditions of an ambient temperature of 25±2°C, a charge/discharge rate of 0.5C, and a state of health (SOH) of 70%.
Technical Specification Sheet EverCore-(100-261)kWh-(30-75)kW-LV
Model number | 100kWh-30kW | 100kWh-35kW | 120kWh-30kW | 120kWh-35kW | 261kWh-60kW | 261kWh-75kW |
System | ||||||
Rated capacity | 100.48 kWh | 120.57 kWh | 261.24 kWh | |||
Maximum charge/discharge rate | 0.5P | |||||
Maximum cycle efficiency① | 89% | |||||
Depth of charge and discharge | 0~100% | |||||
Dimensions (Width × Height × Depth) | 1250×2030×1540 mm | 1850×2230×1600 mm | ||||
Dimensions (without inverter) (Width × Height × Depth) | 950×2030×1540 mm | 1400×2230×1600 mm | ||||
Weight | 1490 kg (battery cabinet) + 73 kg (inverter) | 1630 kg (battery cabinet) + 73 kg (inverter) | 2000 kg (battery cabinet) + 170 kg (inverter) | |||
Operating temperature range | -25~+55℃ | |||||
Storage temperature range | 0~+45℃ | |||||
Operating humidity range | ≤95% (no condensation) | |||||
Maximum operating altitude | 4000 m | |||||
System temperature control method | Industrial-grade air conditioner (battery cabinet); air-cooled (battery pack); intelligent air cooling (inverter) | |||||
Fire suppression method | Standard configuration: aerosol fire suppression system, explosion-proof pressure relief valve, water-based fire suppression system, and audible‑visual alarm; Optional equipment: combustible gas detector, explosion‑proof panel, and explosion‑proof ventilation system. | |||||
Protection rating | IP55 (battery cabinet) + IP66 (inverter) | |||||
Corrosion Protection Grade (Battery Cabinet) | C4/C5 (optional) | |||||
Corrosion Resistance Grade (Inverter) | C5 | |||||
Noise (rated operating condition) | 70 dB(A) @1 m | 75 dB(A) @1 m | ||||
Lightning protection level | AC Secondary / DC Secondary (Photovoltaic & Battery) | |||||
Protection method | Anti-islanding protection, residual current detection, insulation impedance monitoring, AC overcurrent protection, and protection against incorrect AC cable connections, among others. | |||||
Certification Standards | IEC62619, IEC61000-6-2/4, IEC62040, IEC63056, IEC62477, UN38.3 | |||||
Battery | ||||||
Cell type | LFP 3.2V/314Ah | |||||
Cell cycle life② | 8000 | |||||
System Battery Configuration | 1P100S | 1P120S | 1P260S | |||
Rated voltage | 320V | 384V | 832V | |||
Operating voltage range | 290~360V | 348~432V | 754~936V | |||
Rated current | 157A | |||||
Number of battery packs | 5 | 6 | 13 | |||
Battery pack capacity | 20.09 kWh | |||||
Battery pack weight | 198 kg | |||||
Inverter | ||||||
Product model | S6-EH3P30K-H-LV(2LA) | S6-EH3P35K-H-LV(2LA) | S6-EH3P30K-H-LV(2LA) | S6-EH3P35K-H-LV(2LA) | S6-EH3P60K10-LV-YD-H | S6-EH3P75K10-NV-YD-H |
Rated output power | 30 kW | 35 kW | 30 kW | 35 kW | 60 kW | 75 kW |
Maximum output apparent power | 30 kVA | 35 kVA | 30 kVA | 35 kVA | 60 kVA | 75 kVA |
Rated grid voltage | 3/N/PE, 127V/220V3/N/PE, 133V/230V | |||||
Rated grid frequency | 50 Hz / 60 Hz | |||||
Communication frequency range | 45-55 Hz / 55-65 Hz | |||||
Rated output current | 78.7A / 75.3A | 91.8A / 87.8A | 78.7A / 75.3A | 91.8A / 87.8A | 157.5A / 150.6A | 196.8A / 188.2A |
Maximum output apparent power | 1.5 times the rated overload, for 10 seconds; 1.6 times the rated overload, for 2 seconds. | 1.6 times the rated overload, for 10 seconds; 2 times the rated overload, for 200 milliseconds. | ||||
And grid‑off switching time | ≤10 ms | |||||
Power factor | >0.99 (0.8 leading to 0.8 lagging) | |||||
Total Current/Voltage Harmonic Distortion Rate | <2% / <3% | |||||
Recommended Maximum PV Module Power | 60 kW | 70 kW | 60 kW | 70 kW | 120 kW | 150 kW |
Maximum Available PV Input Power | 60 kW | 70 kW | 60 kW | 70 kW | 120 kW | 150 kW |
Maximum input voltage | 1000 V | |||||
Rated voltage | 600 V | |||||
Starting voltage | 180 V | |||||
MPPT voltage range | 150-850 V | 150-950 V | ||||
Maximum input current | 3×42 A | 10×42 A | ||||
Maximum short-circuit current | 3×60 A | 10×60 A | ||||
Number of MPPTs / Maximum Number of Input Strings | 3/6 | 10/20 | ||||
Communication | Standard configuration: WiFi + LAN + Bluetooth, CAN‑BMS × 2, CAN‑Parallel × 2, RS485‑Meter, RS485, DRM, DI × 3, DO × 3; Optional: 4G | Standard configuration: WiFi + LAN + Bluetooth, CAN‑BMS × 2, CAN‑Parallel × 2, RS485‑Meter, RS485, DRM, DI × 5, DO × 4; Optional: 4G | ||||
Maximum number of parallel units (in parallel/stand-alone mode) | 10 | |||||
① Rated operating conditions: Test conditions based on an ambient temperature of 25±2°C, a charge–discharge rate of 0.5P, and an AC output voltage of 220 or 230 V.
② This data is provided by the cell manufacturer. It is based on test conditions of an ambient temperature of 25±2°C, a charge/discharge rate of 0.5C, and a state of health (SOH) of 70%.
Packaging and shipping
Customer visit
Customer Feedback
Quotation Inquiry
Please fill in your Contact Us information and your requirements, and we will arrange for a specialist to get in touch with you!
Jinlang Commercial and Industrial Energy Storage System
Inquiry for a quote
Keywords:
Jinlang Technology
Contact Us
Service Hotline (8:00–18:00): 400-682-5699
Phone: +86-15689558243
Corporate email: anyujt@163.com
Address: No. 3566, Chongde Avenue No. 1, Economic Development Zone, Dezhou City, Shandong Province