Product Features
• Multi‑MPPT design, with a maximum string current of 20 A
• Maximum charge and discharge current of 70 A + 70 A / 140 A
• Supports the “PeakShaving” function in both self-consumption and generator modes.
• Supports a short-term 1.6× overload output at the Backup port
• Multiple methods for connecting to the generator, enabling automatic start-up and shutdown control.
• Supports up to 6 units in both grid‑connected and off‑grid parallel operation.
• Integrates battery management and protection functions to extend battery life.
• Supports adaptation to a wider battery voltage range
Product model
S6-EH3P30K-H-LV / S6-EH3P29.9K-H
S6-EH3P30K-H / S6-EH3P37.5K-H
S6-EH3P40K-H / S6-EH3P50K-H
Technical Specification Sheet | S6-EH3P(29.9-50)K-H | ||||||
Product model | 30K-LV | 29.9K | 30K | 37.5K | 40K | 50K | |
DC Input (PV Side) | |||||||
Maximum allowable input power | 42kW | 41.86kW | 42kW | 52.5kW | 56kW | 70kW | |
Maximum input voltage | 1000V | ||||||
Rated input voltage | 600V | ||||||
Starting voltage | 180V | ||||||
MPPT voltage range | 150-850V | ||||||
Maximum input current | 3*40A | 4*40A | |||||
Maximum input short-circuit current | 3*60A | 4*60A | |||||
Number of MPPTs / Maximum Number of Input Strings | 3*6 | 4*8 | |||||
Battery | |||||||
Battery type | Lithium battery | ||||||
Battery voltage range | 150-800V | ||||||
Maximum charge/discharge power | 33kW | 29.9kW | 33kW | 41.3kW | 44kW | 55kW | |
Maximum charge/discharge current | 70 A*2 (1) | ||||||
Number of battery input ports | 2 | ||||||
Communication method | CAN/RS485 | ||||||
AC Output (Grid Side) | |||||||
Rated output power | 30kW | 29.9kW | 30kW | 37.5kW | 40kW | 50kW | |
Maximum output apparent power | 30kVA | 29.9kVA | 30kVA | 37.5kVA | 40kVA | 50kVA | |
Rated grid voltage | 3/N/PE, 220V/230V | 3/N/PE, 380V/400V | |||||
Rated grid frequency | 50Hz/60Hz | ||||||
Rated grid output current | 78.7 A / 75.3 A | 45.4 A / 43.2 A | 45.6 A / 43.3 A | 57 A / 54.1 A | 60.8 A / 57.7 A | 76 A / 72.2 A | |
Maximum output current | 78.7 A / 75.3 A | 45.4 A / 43.2 A | 45.6 A / 43.3 A | 57 A / 54.1 A | 60.8 A / 57.7 A | 76 A / 72.2 A | |
Output power factor | >0.99 (0.8 leading .... 0.8 lagging) | ||||||
Total Current Harmonic Distortion Rate | <3% | ||||||
AC Input (Grid Side) | |||||||
Maximum Continuous Bypass Input Current | 152A | ||||||
Rated input voltage | 3/N/PE, 220V/230V | 3/N/PE, 380 V / 400 V | |||||
Rated input frequency | 50 Hz / 60 Hz | ||||||
Generator input | |||||||
Maximum input power | 30kW | 29.9kW | 30kW | 37.5kW | 40kW | 50kW | |
Rated input voltage | 3/N/PE, 220V/230V | 3/N/PE, 380V/400V | |||||
Rated input frequency | 50Hz/60Hz | ||||||
AC Output (Off-Grid Side) | |||||||
Rated output power | 30kW | 29.9kW | 30kW | 37.5kW | 40kW | 50kW | |
Maximum output apparent power | Supports 2 seconds of continuous output at 1.6 times the rated power. | ||||||
And grid‑off switching time | < 10 ms | ||||||
Rated output voltage | 3/N/PE, 220V/230V | 3/N/PE, 380V/400V | |||||
Rated frequency | 50Hz/60Hz | ||||||
Rated output current | 78.7 A / 75.3 A | 45.4 A / 43.2 A | 45.6 A / 43.3 A | 57 A / 54.1 A | 60.8 A / 57.7 A | 76 A / 72.2 A | |
Total Voltage Harmonic Distortion Rate | < 2% | ||||||
Efficiency | |||||||
Maximum efficiency | 97.6% | ||||||
European Efficiency | 97.0% | ||||||
Maximum charging efficiency of the PV system | 98.5% | ||||||
Maximum charge–discharge efficiency of the battery | 97.5% | ||||||
Protection | |||||||
Island Conservation | possessing | ||||||
AC Output Overcurrent Protection | possessing | ||||||
AC Short-Circuit Protection | possessing | ||||||
Integrated DC switch | Optional | ||||||
DC reverse connection protection | possessing | ||||||
Surge protection | DC secondary / AC secondary | ||||||
Integrated AFCI (Arc Fault Circuit Interrupter) | Optional | ||||||
Basic Parameters | |||||||
Dimensions (Width × Height × Depth) | 530*880*290 mm | ||||||
Weight | 73 kg | ||||||
Topology | Non-isolated type | ||||||
Nighttime self-consumption electricity | <25 W | ||||||
Operating ambient temperature / humidity | -25 ~ +60℃ / 0 ~ 95% | ||||||
Protection rating | IP66 | ||||||
Noise (typical) | <65dB(A) | ||||||
Cooling method | Intelligent Redundant Air Cooling | ||||||
Maximum operating altitude | 4000 m | ||||||
Grid-connection standard | G98, G99, VDE-AR-N 4105 / VDEV 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, IEC 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA | ||||||
Safety / EMC Standards | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-3 | ||||||
Characteristics | |||||||
PV port | MC4 quick connector | ||||||
Battery port | OT terminal | ||||||
Communication port | OT terminal | ||||||
Display screen | LED + Bluetooth + App | ||||||
Communication method | CAN / RS485 / Ethernet / Wi‑Fi (optional) / Cellular (optional) / LAN (optional) | ||||||
Packaging and shipping
Customer visit
Customer Feedback
Quotation Inquiry
Please fill in your Contact Us information and your requirements, and we will arrange for a specialist to get in touch with you!
Jinlang Three-Phase High-Voltage Energy Storage Inverter S6-EH3P (29.9–50) kV-H
Inquiry for a quote
Keywords:
Jinlang Technology
Contact Us
Service Hotline (8:00–18:00): 400-682-5699
Phone: +86-15689558243
Corporate email: anyujt@163.com
Address: No. 3566, Chongde Avenue No. 1, Economic Development Zone, Dezhou City, Shandong Province